MESA

The Metl-Span Striated Mesa insulated wall panel is an attractive and economical alternative to typical flat wall panels. The exterior face is lightly profiled with narrow longitudinal striations and exhibits a virtual flat appearance from a short distance away. The Striated wall panel is an exceptional value combining the aesthetics of a flat wall panel and high insulation ratings of a polyurethane core.


Note: Not intended for exterior walls on cold storage buildings.

01

Exterior Profile:

Longitudinal striations, nominal 1/32″ deep

02

Interior Profile:

Mesa nominal 1/8″ deep; Light Mesa nominal 1/16″ deep

03

Panel Core:

Foamed-in-place, Non-CFC & zero ODP polyurethane, FM Class 1 approval

04

Thermal Values:

K-factor, Btu in/ft2 hr. °F @ 75°F (24°C) mean core temperature = 0.140

K-factor, Btu in/ft2 hr. °F @ 40°F (4°C) mean core temperature = 0.126

05

Module Width:

30″, 36″, 42″

06

Panel Thickness:

2″, 2 1/2″, 3″ (2 3/4″ thickness also available from Nevada plant)

07

Panel Lengths:

8′-0″ to 40′-0″ for the 30″ & 36″ widths, 8′-0″ to 32′-0″ for the 42″ width

08

Exterior Facings:

Stucco embossed, G-90 galvanized and/or AZ-50 aluminum-zinc coated steel in 24 Ga. and 22 Ga.

09

Interior Facings:

Stucco embossed, G-90 galvanized and/or AZ-50 aluminum-zinc coated steel in 26 Ga., 24 Ga. and 22 Ga.

10

Panel Joint:

Offset double tongue and groove with extended metal shelf for positive face fastening

11

Fastening:

Fastener and Clip concealed in the side joint

12

Color:

A full range of exterior colors & coatings are available for the architectural market. For specific information about our available colors and coatings, visit us online for a comprehensive selection.

attributes & advantages

Metl-Span’s Mesa insulated wall panel with a urethane foam core have a standard FM Class 1 approval and offer the best insulating values available today.


Panels are lightweight and quick to install, significantly reducing construction time.


A double tongue-and-groove offset side joint permits concealed fastening.


Consistent insulating values are achieved with built-in thermal breaks, saving energy.


The metal and foam composite construction creates a rigid panel far stronger than the individual parts. This increases the span capability of the panels and reduces the need for secondary structural steel components.

mesa - material specifications

Exterior Profile: Longitudinal striations, nominal 1/32″ deep.
Interior Profile: Light Mesa wave pattern, nominal 1/16″ deep.
Foam Core: Foamed-in-place, Non-CFC & zero ODP polyurethane, Factory Mutual Class 1 approval.
Thermal Values: R-Values with Air Films 75° Mean 40° Mean
2″ Panel 15.14 17.03
2-1/2″ Panel 18.71 21.29
2-3/4″ Panel 20.49 23.42
3″ Panel 22.27 25.55

• R-Values include the air films on each side of the panel.

• 75° Mean based on ASTM C518 Thermal Testing. 40° Mean based on ASTM C1363 Thermal Testing (Values for C1363 based on 4″ panel testing). All values for other thicknesses extrapolated.

Module Width: 30″, 36″ & 42″
Panel Thickness: 2″, 2-1/2″, 2-3/4″ & 3″
Panel Lengths: Standard 8′-0″ to 40′-0″ for 30″ and 36″ widths.
Standard 8′-0″ to 32′ -0″ for 42″ width.
Horizontal Application Reveal Widths: 1/4″, 1/2″, 3/4″, 1″, 1-1/2″, 2″, 2-1/2″, 3″
Exterior Facings: Stucco embossed, G-90 galvanized and/or AZ-50 aluminum-zinc coated steel in 24 Ga. and 22 Ga.
Interior Facings: Stucco embossed, G-90 galvanized and/or AZ-50 aluminum-zinc coated steel in 26 Ga., 24 Ga. and 22 Ga.
Standard Exterior: Full-Strength 70% PVDF Fluoropolymer Coating.
Finishes & Colors:

Polar White, Sandstone, Regal Gray, Desert Beige* and Dark Bronze*.
*Desert Beige and Dark Bronze are premium colors in 22 Ga. thickness.

Note:
1. A new expanded palette of premium colors is also available for non-cold storage buildings.
2. Dark colors are not recommended for exterior color on cooler and freezer buildings.
3. Prices may vary by color, gauge and quantity of metal.

Interior Finishes & Colors: USDA-compliant Polyester, Igloo White.
Joint: Offset double tongue and groove with extended metal shelf for positive face fastening.
Fastening: Fastener & Clip concealed in the side joint.

load span tables

CF-42 STRIATED WALL PANEL ALLOWABLE CONNECTION LOAD (PSF)
PANEL
THICKNESS
SPAN
CONDITION
FASTENING
PATTERN
PANEL SPAN (FT)
5 6 7 8 9 10 11 12
2″ Thick Two
Spans
Pattern FP1 31.6 25.8 21.7 18.8 16.5 14.8 13.3 12.2
Pattern FP2 46.2 37.7 31.8 27.5 24.2 21.6 19.5 17.8
Pattern FP3 58.3 47.6 40.2 34.7 30.5 26.0 22.1 19.0
Three Or
More Spans
Pattern FP1 33.1 27.4 23.4 20.4 18.1 16.2 14.7 13.5
Pattern FP2 48.4 40.1 34.2 29.8 26.4 23.7 21.2 18.0
Pattern FP3 61.1 50.6 43.2 36.5 30.2 25.2 21.2 18.0
2.5″ Thick Two
Spans
Pattern FP1 33.3 27.2 22.9 19.8 17.4 15.5 14.0 12.7
Pattern FP2 47.5 38.8 32.7 28.2 24.8 22.1 19.9 18.2
Pattern FP3 60.1 49.0 41.3 35.7 31.4 28.0 25.2 23.0
Three Or
More Spans
Pattern FP1 34.6 28.6 24.4 21.3 18.8 16.9 15.3 14.0
Pattern FP2 49.3 40.8 34.8 30.3 26.8 24.1 21.9 20.0
Pattern FP3 62.4 51.6 44.0 38.3 33.9 30.5 27.7 24.7
3″ Thick Two
Spans
Pattern FP1 35.1 28.7 24.1 20.8 18.3 16.3 14.7 13.4
Pattern FP2 48.8 39.8 33.6 28.9 25.4 22.6 20.4 18.6
Pattern FP3 61.8 50.5 42.5 36.7 32.2 28.7 25.9 23.5
Pattern FP4 71.1 58.0 48.9 42.2 37.0 33.0 29.7 27.1
Three Or
More Spans
Pattern FP1 36.1 29.9 25.4 22.2 19.6 17.6 16.0 14.6
Pattern FP2 50.2 41.5 35.4 30.8 27.3 24.5 22.2 20.3
Pattern FP3 63.7 52.6 44.8 39.0 34.6 31.0 28.2 25.8
Pattern FP4 73.2 60.5 51.5 44.9 39.7 35.7 32.4 29.6
CF-36 STRIATED WALL PANEL ALLOWABLE CONNECTION LOAD (PSF)
PANEL
THICKNESS
SPAN
CONDITION
FASTENING
PATTERN
PANEL SPAN (FT)
5 6 7 8 9 10 11 12
2″ Thick Two
Spans
Pattern FP1 40.5 34.6 30.3 26.8 23.6 21.0 19.0 17.3
2.5″ Thick Pattern FP1 45.0 38.5 33.7 30.1 27.1 24.1 21.8 19.8
3″ Thick Pattern FP1 49.0 41.8 36.6 32.7 29.5 26.9 24.3 22.2
2″ Thick Three Or
More Spans
Pattern FP1 41.4 35.1 30.4 26.8 24.0 21.7 19.8 18.2
2.5″ Thick Pattern FP1 46.3 39.3 34.1 30.2 27.0 24.4 22.3 20.5
3″ Thick Pattern FP1 50.5 42.9 37.3 33.1 29.6 26.9 24.6 22.6
CF STRIATED WALL PANEL ALLOWABLE POSITIVE LOAD (PSF)
PANEL
THICKNESS
SPAN
CONDITION
DESIGN
CRITERIA
PANEL SPAN (FT)
5 6 7
8
9 10 11 12
2″ Thick Two
Spans
Bending & Shear 72.4 59.2 49.9 43.1 38.0 31.1 24.8 20.2
Deflection (L/180) 71.5 56.3 45.6 37.6 31.4 26.6 22.7 19.5
Three Or
More Spans
Bending & Shear 71.2 58.6 49.8 43.3 38.3 34.1 27.7 23.0
Deflection (L/180) 72.3 56.8 45.7 37.3 30.9 25.8 21.7 18.4
2.5″ Thick Two
Spans
Bending & Shear 82.8 67.6 57.0 49.2 43.2 38.6 30.4 24.6
Deflection (L/180) 87.2 69.4 56.7 47.2 39.9 34.1 29.4 25.5
Three Or
More Spans
Bending & Shear 81.1 66.6 56.5 49.1 43.4 38.9 32.9 27.2
Deflection (L/180) 88.2 70.1 57.1 47.3 39.7 33.6 28.7 24.7
3″ Thick Two
Spans
Bending & Shear 92.4 75.5 63.6 54.8 48.1 42.9 35.5 28.5
Deflection (L/180) 100.4 80.4 66.1 55.5 47.2 40.7 35.3 30.9
Three Or
More Spans
Bending & Shear 90.1 73.9 62.6 54.3 48.0 42.9 37.0 30.4
Deflection (L/180) 101.4 81.3 66.8 55.9 47.4 40.6 35.0 30.4
  • Based on CF-36 and CF-42 panel with 26 ga. Santa Fe exterior & 26 ga. Light Mesa interior faces (min Fy=33 ksi).
  • For pattern FP1, CF panel clips are fastened to minimum 14 gage steel with (2) 1/4″-14 SDS Tek 3 at interior supports and (1) 1/4″-14 SDS Tek 3 at end supports. For 12 gage or thicker steel, #12-24 SDS or 1/4″-14 SDS Tek 5′s may be used. In lieu of self-drilling screws, self-tapping screws may be used.
  • Fastening patterns FP2, FP3, FP4, and FP5, includes CF panel clip attachment plus 1, 2, 3 or 4 Fabloks, respectively, at supports per panel width. Fab-lok spacing is 10.5″ OC from the female edge of the panel seam.
  • The through fasteners (FP9) are as follows: #12-24 SDS in min 12 ga. steel; or #1/4-14 SDS in min 12 ga. steel; or #1/4-14 STS in min 14 ga. steel. 4 Fasteners with 5/8″ neoprene bonded washers per panel width @ max 8.4″ OC.
  • The through fasteners (FP10) are as follows: #12-24 SDS in min 12 ga. steel; or #1/4-14 SDS in min 12 ga. steel; or #1/4-14 STS in min 14 ga. steel. 5 Fasteners with 5/8″ neoprene bonded washers per panel width @ max 8.4″ OC.
  • The allowable suction load is the lowest value of panel bending strength, shear strength, deflection limit and connection strength for each fastening pattern.
  • Allowable loads based on panel stress and deflection design criteria are derived from ASTM E72 structural testing and calculated with factor of safety of 2.5 for bending stress, 3.0 for shear stresses and deflection limitation of L/180.
  • The panel connection strength was determined from ASTM E1592 testing and the allowable loads are calculated with the factor of safety of 2.
  • The structural capacity of the girts are not considered and must be examined independently.
  • Consult Metl-Span for recommendations on panel profile and gage suitable for thermal stresses.
CF-30 STRIATED WALL PANEL ALLOWABLE CONNECTION LOAD (PSF)
PANEL
THICKNESS
SPAN
CONDITION
FASTENING
PATTERN
PANEL SPAN (FT)
5 6 7 8 9 10 11 12
2″ Thick Two
Spans
Pattern FP1 48.6 41.6 36.4 32.1 28.3 25.2 21.2 17.3
2.5″ Thick Pattern FP1 54.1 46.2 40.5 36.1 32.5 29.0 26.1 21.5
3″ Thick Pattern FP1 58.8 50.2 44.0 39.2 35.4 32.3 29.2 25.5
2″ Thick Three Or
More Spans
Pattern FP1 49.7 42.1 36.5 32.2 28.8 26.0 22.0 18.7
2.5″ Thick Pattern FP1 55.6 47.1 41.0 36.2 32.4 29.3 26.8 23.7
3″ Thick Pattern FP1 60.6 51.5 44.8 39.7 35.6 32.2 29.5 27.1
  • Based on CF-30, CF-36 and CF-42 panel with 26 ga. Striated exterior & 26 ga. Light Mesa interior faces (min Fy=33 ksi).
  • For pattern FP1, CF panel clips are fastened to minimum 14 gage steel with (2) 1/4″-14 SDS Tek 3 at interior supports and (1) 1/4″-14 SDS Tek 3 at end supports. For 12 gage or thicker steel, #12-24 SDS or 1/4-14 SDS Tek 5’s may be used. In lieu of self-drilling screws, self-tapping screws may be used.
  • Fastening patterns FP2, FP3, FP4, and FP5, includes CF panel clip attachment plus 1, 2, 3 or 4 Fabloks, respectively, at supports per panel width. Fab-lok spacing is 10.5″ OC from the female edge of panel seam.
  • The through fasteners (FP9) are as follows: #12-24 SDS in min 12 ga. steel; or #1/4-14 SDS in min 12 ga. steel; or #1/4-14 STS in min 14 ga. steel. 4 Fasteners with 5/8″ neoprene bonded washers per panel width @ max 8.4″ OC.
  • The through fasteners (FP10) are as follows: #12-24 SDS in min 12 ga steel; or #1/4-14 SDS in min 12 ga. steel; or #1/4-14 STS in min 14 ga. steel. 5 Fasteners with 5/8″ neoprene bonded washers per panel width @ max 8.4″ OC.
  • The allowable suction load is the lowest value of panel bending strength, shear strength, deflection limit and connection strength for each fastening pattern.
  • Allowable loads based on panel stress and deflection design criteria are derived from ASTM E72 structural testing and calculated with factor of safety of 2.5 for bending stress, 3.0 for shear stresses and deflection limitation of L/180.
  • The panel connection strength was determined from ASTM E1592 testing and the allowable loads are calculated with the factor of safety of 2.
  • The structural capacity of the girts was not considered and must be examined independently.
  • Consult Metl-Span for recommendations on panel profile and gage suitable for thermal stresses.

Takura Steel Buildings offers metl-span insulated panels to clients across Ontario, British Columbia, Alberta, Saskatchewan, Manitoba, Quebec, New Brunswick, Newfoundland and Labrador, Yukon, Northwest Territories, and Nunavut.